Inspect The Battery - Genie S-60 TraX Service Manual

Hide thumbs Also See for S-60 TraX:
Table of Contents

Advertisement

Section 3 • Scheduled Maintenance Procedures
Checklist B Procedures
B-1

Inspect the Battery

Genie specifications require that this procedure be
performed every 250 hours or quarterly, whichever
comes first.
Proper battery condition is essential to good engine
performance and operational safety. Improper fluid
levels or damaged cables and connections can
result in engine component damage and hazardous
conditions.
Electrocution/burn hazard. Contact
with hot or live circuits could result
in death or serious injury. Remove
all rings, watches and other
jewelry.
Bodily injury hazard. Batteries
contain acid. Avoid spilling or
contacting battery acid. Neutralize
battery acid spills with baking soda
and water.
1 Put on protective clothing and eye wear.
2 Be sure that the battery cable connections are
free of corrosion.
Note: Adding terminal protectors and a corrosion
preventative sealant will help eliminate corrosion on
the battery terminals and cables.
3 Be sure that the battery hold downs and cable
connections are tight.
3 - 20
4 Be sure that the battery separator wire
5 Fully charge the battery(s) and allow the
6 Remove the battery vent caps and check the
7 Check the ambient air temperature and adjust
• Add 0.004 to the reading of each cell for
• Subtract 0.004 from the reading of each cell for
8 Perform an equalizing charge OR fully charge
9 Remove the battery vent caps and check the
S-60 • S-65 • S-60 TRAX • S-65 TRAX
S-60 HC • S-60X • S-60XC
connections are tight (if equipped).
battery(s) to rest at least 6 hours.
specific gravity of each battery cell with a
hydrometer. Note the results.
the specific gravity reading for each cell as
follows:
every 10° / 5.5° C above 80° F / 26.7° C.
every 10° / 5.5° C below 80° F / 26.7° C.
Result: All battery cells display an adjusted
specific gravity of 1.277 or higher. The battery
is fully charged. Proceed to step 11.
Result: One or more battery cells display a
specific gravity of 1.217 or below. Proceed to
step 8.
the battery(s) and allow the battery(s) to rest at
least 6 hours.
specific gravity of each battery cell with a
hydrometer. Note the results.
December 2013
Part No. 147753

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

S-65 traxS-60xS-60xc

Table of Contents