December 2013
Error Source
ID Name
21 Primary Up / Down
Joystick
22 Primary
Up / Down
Directional
Valves
23 Primary
Up / Down
Flow Valve
24 Angle sensor
Part No. 147753
Error Type
ID Name
11 Value at 5V
12 Value too high
15 Value too low
16 Value at 0V
17 Not calibrated
21 Fault
12 Value too high
15 Value too low
17 Not calibrated
11 Value at 5V
12 Value too high
15 Value too low
16 Value at 0V
17 Not calibrated
31 Invalid setup
S-60 • S-65 • S-60 TRAX • S-65 TRAX
S-60 HC • S-60X • S-60XC
Control System Fault Codes
Condition
Function is
inoperative.
Alarm sounds
indicating a fault.
Valve is operating
outside of limits.
Alarm sounds
indicating a fault.
Valve is operating
outside of limits.
Alarm sounds
indicating a fault.
Normal function
except threshold
for one or both
directions is zero.
Reduced speed
function.
Alarm sounds
indicating a fault.
Initiate 1 -second
beep of Alarm Buzzer
and required retract
into safe envelope
Section 5 • Fault Codes
Solution
Cycle power off,
then on after
problem has been
corrected.
Calibrate joystick.
Cycle power off,
then on after
problem has been
corrected.
Cycle power off,
then on after
problem has been
corrected.
Calibrate valve
threshold.
Cycle power off,
then on after
problem has been
corrected.
Calibrate angle sensor.
Calibrate angle sensor.