Vsg Adjustment Result - Ricoh M065 Service Manual

Gestetner, lanier, savin
Table of Contents

Advertisement

Vsg Adjustment Result

SP3-325-001 to -010 (Vsg Adjustment Result)
No. Result
Description
Vsg adjustment
1
O.K
is correctly done.
ID sensor
Vsg cannot be
2
adjustment
adjusted within
error
4.0 ±0.5V.
ID sensor output
is more than
ID sensor
3
"Voffset
output error
Threshold"
(SP3-324-004)
Vsg
Vsg adjustment
9
Adjustment
has not been
error
completed.
SM Appendix
Possible Causes/Action
-
Dirty ID sensor (toner, dust, or foreign
material)
Dirty transfer belt
Scratched image transfer belt
Defective ID sensor
Poor connection
Defective IOB
1.
Clean the ID sensor.
2.
Check the belt cleaning. Clean or replace the
transfer belt.
3.
Replace the image transfer belt.
4.
Replace the ID sensor.
5.
Check the connection.
6.
Replace the IOB board.
Defective ID sensor
Poor connection
Defective IOB
1.
Replace the ID sensor.
2.
Check the connection.
3.
Replace the IOB board.
Other cases
Retry SP3-321-010.
4-5
Process Control Results
M065/M066

Advertisement

Table of Contents
loading