No.
Type
Details (Symptom, Possible Cause, Troubleshooting Procedures)
Heating roller fusing lamp overheat 2 (software error)
The detected pressure roller temperature stays at 230°C or more for 1
second.
Defective PSU
553
A
Defective BCU
1.
Replace the heating roller thermistor (end).
2.
Replace the PSU.
3.
Replace the BCU.
No.
Type
Details (Symptom, Possible Cause, Troubleshooting Procedures)
Heating roller fusing lamp overheat 2 (hardware error)
The heating roller thermistor (end) detects 250°C or more.
Defective heating roller thermistor (end)
Defective PSU
554
A
Defective BCU
Defective fusing control system
1.
Replace the heating roller thermistor (end).
2.
Replace the PSU.
3.
Replace the BCU.