System Service Mode
[Initial Process Control Setting]
Adjusts the threshold for the process control at power on.
3522
When the current condition has changed by more than the values of these SPs
when compared with the conditions at the previous operation, the process
control at power on is executed.
002 Non-use Time Setting
003 Temp. Range
004 Relative Humidity Change
005 Absolute Humidity Change
[Rapi Timer]
100
Time Setting
Adjusts the time-out time to get the Rapi timer.
[Non-use Time Process Control Setting]
Adjusts the threshold for the process control at stand-by.
3531
When the current condition has changed by more than the values of these SPs
when compared with the conditions at the previous operation, the process
control at stand-by is executed.
001 Non-use Time Setting
002 Temp. Range
Relative Humidity
003
Change
Absolute Humidity
004
Change
Maximum Execution
005
Number
M065/M066
*ENG
[0 to 1440 / 360 / 1 minute/step]
*ENG
[0 to 99 / 10 / 1 deg/step]
*ENG
[0 to 99 / 50 / 1 %RH/step]
*ENG
[0 to 99 / 6 / 1 g/m
*ENG
[0 to 255 / 30 / 1 sec/step]
*ENG
[0 to 1440 / 360 / 1 minute/step]
*ENG
[0 to 99 / 10 / 1 deg/step]
*ENG
[0 to 99 / 50 / 1 %RH/step]
*ENG
[0 to 99 / 6 / 1 g/m
Adjusts the maximum execution time for
*ENG
the process control at stand-by.
[0 to 99 / 10 / 1 time/step]
8-218
3
/step]
3
/step]
SM Appendix