Ricoh M065 Service Manual page 317

Gestetner, lanier, savin
Table of Contents

Advertisement

Rev. 12/14/2011
No.
Type
FGATE OFF error: C
237
D
See SC 230 for troubleshooting details.
No.
Type
240
C
LD error: K or C
241
C
LD error: Y or M
The bridge board detects LDB error a few times consecutively when
LDB unit turns on after LDB initialization.
-
-
1.
2.
3.
SM Appendix
Details (Symptom, Possible Cause, Troubleshooting Procedures)
The PFGATE ON signal still asserts within 5 seconds after
processing the image in normal job or MUSIC (line position
adjustment) for end position [C].
The PFGATE ON signal still asserts when the next job starts.
Details (Symptom, Possible Cause, Troubleshooting Procedures)
Worn-out LD
Disconnected or broken harness of the LD
Replace the harness of the LD.
Replace the laser unit.
Replace the bridge board.
3-7
SC Tables
M065/M066

Advertisement

Table of Contents
loading