[Stand-by Mode Setting]
001
Wait Time AF Ready
Wait Time AF Recovery
003
Specifies the time for keeping the target temperature without any jobs after
recovery (SP1105-083).
Wait Time AF Job
004
Specifies the time for keeping the target temperature without any jobs after a
last job.
P-Roll Thresh AF Ready
005
Specifies the threshold temperature of the pressure roller for entering the wait
time mode (SP1-113-001).
P-Roll Thresh AF Job
006
Specifies the threshold temperature of the pressure roller for entering the wait
time mode (SP1-113-004).
On/Off SW Timer
008
Specifies the interval for entering the PID control from the On/Off control.
SM Appendix
*ENG
[0 to 60 / 30 / 1 sec/step]
*ENG
[0 to 60 / 10 / 1 sec/step]
*ENG
[0 to 60 / 10 / 1 sec/step]
*ENG
[0 to 160 / 120 / 1 deg/step]
*ENG
[0 to 160 / 100 / 1 deg/step]
*ENG
[0 to 999 / 300 / 1 sec/step]