5930
[Meter Click Charge]
Setting
Switches the meter-click charge mode on and off.
[0: OFF], [1: ON]
Important: Turn the main switch off/on after changing this setting.
OFF:
Meter charge mode disabled (default). This setting is for machines were the
operator is responsible for replacing the PCDU, the ITB unit, and the fusing unit.
Alert messages are displayed on the operation panel when the PCDU, the ITB
001
unit, and the fusing unit reach the limit of their yield.
ON:
Meter charge mode enabled. This setting is for machines which the service
technician has responsibility for servicing.
Alert messages are not displayed when the PCDU, the ITB unit, and the
fusing unit reach the limits of their yield.
If the setting of SP5-930-001 is set to "1 (enabled)", the settings of
SP5-930-010, -014 and -016 must be adjusted.
010 PCDU
014 ITB Unit
SM Appendix
*ENG
-
Displays or does not display the
end display for the PCDU. This
SP is activated only when the
*ENG
SP5930-001 is set to "1".
[0 or 1 / 1 / -]
0: OFF, 1: ON
Displays or does not display the
end display for the ITB unit. This
SP is activated only when the
*ENG
SP5930-001 is set to "1".
[0 or 1 / 1 / -]
0: OFF, 1: ON
8-273
System Service Mode
M065/M066