Ricoh M065 Service Manual page 630

Gestetner, lanier, savin
Table of Contents

Advertisement

System Service Mode
014 K (Max Correction)
015 C (Max Correction)
016 M (Max Correction)
017 Y (Max Correction)
018 K (Max Abs Hum)
019 C (Max Abs Hum)
020 M (Max Abs Hum)
021 Y (Max Abs Hum)
[Vk Display]
3612
Displays Vk for each color.
001 Bk
002 C
003 M
004 Y
[Dev. DC Control:Display]
Standard: 260 mm/sec, Middle: 182 mm/sec, Low: 85 mm/sec
3621
Displays the development DC bias adjusted with the process control for each
line speed and color.
001 Standard Speed:Bk
002 Standard Speed:C
003 Standard Speed:M
004 Standard Speed:Y
005 Middle Speed:Bk
006 Middle Speed:C
M065/M066
*ENG
*ENG
[0 to 5 / 0.23 / 0.01 mg/cm2/kv/step]
*ENG
*ENG
*ENG
*ENG
[1 to 99 / 10 / 1 g/m3/step]
*ENG
*ENG
*ENG
*ENG
[-300 to 300 / 0 / 1 V/step]
*ENG
*ENG
*ENG
*ENG
*ENG
[0 to 800 / 550 / 1 -V/step]
*ENG
*ENG
*ENG
8-220