SC Tables
No.
Type
Details (Symptom, Possible Cause, Troubleshooting Procedures)
360
D
TD sensor (Vt high) error 1: K
361
D
TD sensor (Vt high) error 1: M
362
D
TD sensor (Vt high) error 1: C
363
D
TD sensor (Vt high) error 1: Y
-
-
1.
2.
3.
M065/M066
The Vt value of the black, magenta, cyan, or yellow TD sensor
exceeds the specified value (default: 4.7V) with SP3020-002
twenty counts.
The [Vt - Vtref] value of the black, magenta, cyan, or yellow TD
sensor exceeds the specified value (default: 5.0V) with
SP3020-001.
Black, magenta, cyan, or yellow TD sensor disconnected
Harness between TD sensor and development unit defective
Defective TD sensor.
Check the black, magenta, cyan, or yellow TD sensor connector
and harness between the TD sensor and PCDU for damage.
Check the drawer connector of the PCDU.
Replace the PCDU.