Process Control Results
No.
Result
9
Vcnt error 3
The machine starts developer initialization after you set "Enable" in SP3-902-005,
006, 007, or 008. Developer initialization automatically resumes when you open
and close the front door or turn the main switch off and on if an error other than
Error 8 occurs.
M065/M066
Description
±0.2V.
Vcnt is less than 4.7V.
4-2
Possible Causes/Action
1.
Make sure that the heat seal on the
development unit is not removed
2.
Defective TD sensor
3.
Vt target settings are not correct.
4.
Toner density error