4.2.3 LINE POSITION ADJUSTMENT RESULT

SP5-993-007 (Line Position Adjustment > Result)
No.
Result
Successfully
01
completed
Out of adjustment
02
range
(over ±1.4 mm)
Calculation Error
03
04
Sampling Error
Descending slope
05
error
Ascending slope
06
error
Pattern lines
07
mismatch
(less than 64 lines)
Sampling time-out
08
Sampling start
09
error
Pattern length
10
mismatch
Pattern lines
11
mismatch
(over 64 lines)
Magnification
12
mismatch
Toner condition
13
Not executed
17
Potential control
18
error
Note: Concerning the error codes (05, 06, 07 or 10) which stop sampling data
when either the front, center, or rear ID sensor detect an error, the machine
may display the error code for both ID sensors in some cases.
For the possible causes of the errors in the line position adjustment, see Model J-
P2 Service Manual.
PROCESS CONTROL ERROR CONDITIONS
Description
Data sampling was correctly done and line position
adjustment was successfully completed.
The calculated result for line position correction is
greater than ±1.4 mm.
Distance between the lines is greater than ±1.4 mm.
Data sampling cannot be done properly.
The ascending or descending slope of the ID sensor
signal wave is out of specification.
The detected number of pattern lines is less than 64.
Data sampling cannot be done within the allocated
time.
The start mark cannot be detected within the
allocated time.
The pattern length is shorter or longer than specified.
The detected number of pattern lines is over 64.
The calculated magnification value does not match
any data in the laser power frequency adjustment
data table.
The machine is in the toner near-end or toner end
condition.
The machine is not ready to do the line position
adjustment manually from the user menu.
Line position adjustment cannot be done due to
failed potential control.