System Service Mode
[Thick 1: Switch Timing: T-Edge] DFU
Adjusts the bias/voltage switch timing of the paper transfer roller/discharge
2524
plate at the paper trailing edge between the erase margin area and the image
area.
Middle: 182 mm/sec, Low: 85 mm/sec
001 Paper Transfer: 1st
002 Paper Transfer: 2nd
003 Paper Transfer: Low: 1st
004 Paper Transfer: Low: 2nd
005 Separation DC: Middle: 1st
006 Separation DC: Middle: 2nd
007 Separation DC: Low: 1st
008 Separation DC: Low: 2nd
2530
[Thick 1: Env. Correct Table] DFU
013 Separation DC: Middle: 1st
014 Separation DC: Middle: 2nd
015 Separation DC: Low: 1st
016 Separation DC: Low: 2nd
[Thick 1: Edge-Env. Correct] DFU
017 Separation DC: Middle: 1st
018 Separation DC: Middle: 2nd
019 Separation DC: Low: 1st
020 Separation DC: Low: 2nd
M065/M066
*ENG
*ENG
*ENG
*ENG
[0 to 50 / 0 / 2 mm/step]
*ENG
*ENG
*ENG
*ENG
*ENG
*ENG
[1 to 100 / 30 / 1 /step]
*ENG
*ENG
*ENG
*ENG
[1 to 100 / 30 / 1 /step]
*ENG
*ENG
8-108