[Charge AC A: MH] DFU
Charge Roller AC Current Adjustment for MH (Color)
2010
Displays/sets the AC current target of the charge roller for MH environment
(Middle temperature and High humidity).
001 Environmental Target: Bk
002 Environmental Target: C
003 Environmental Target: M
004 Environmental Target: Y
[Charge AC A: HH] DFU
Charge Roller AC Current Adjustment for HH (Color)
2011
Displays/sets the AC current target of the charge roller for HH environment
(High temperature and High humidity).
001 Environmental Target: Bk
002 Environmental Target: C
003 Environmental Target: M
004 Environmental Target: Y
2012
[Charge Output Control] DFU
001 AC Voltage
SM Appendix
*ENG
[0 to 3000 / 820 / 10
*ENG
*ENG
[0 to 3000 / 840 / 10
*ENG
[0 to 3000 / 880 / 10
*ENG
[0 to 3000 / 860 / 10
*ENG
*ENG
[0 to 3000 / 840 / 10
*ENG
[0 to 3000 / 940 / 10
Selects the AC voltage control type.
[0 or 1 / 0 / 1 /step]
*ENG
0: Process control
1: Manual control (AC voltages are
decided with SP2006.)
8-31
System Service Mode
A/step]
A/step]
A/step]
A/step]
A/step]
A/step]