Ricoh M065 Service Manual page 609

Gestetner, lanier, savin
Table of Contents

Advertisement

007 (-)Consumption: M
008 (-)Consumption: Y
009-012 Threshold for development gamma rank.
009 P Rank 1 Threshold
010 P Rank 2 Threshold
011 P Rank 3 Threshold
012 P Rank 4 Threshold
013-014 Threshold for image density rank on the image transfer belt.
013 T Rank 1 Threshold
014 T Rank 2 Threshold
015 Correct Value Coef
3241
[Background Potential Setting]
001 Coefficient: Bk
002 Coefficient: C
003 Coefficient: M
004 Coefficient: Y
005 Offset: Bk
006 Offset: C
007 Offset: M
008 Offset: Y
SM Appendix
*ENG
*ENG
*ENG
[0 to 2 / 0.5 / 0.01 /step]
*ENG
[0 to 2 / 0.25 / 0.01 /step]
*ENG
[-2 to 0 / -0.25 / 0.01 /step]
*ENG
[-2 to 0 / -0.5 / 0.01 /step]
*ENG
[-1 to 0 / -0.16 / 0.01 V/step]
*ENG
[0 to 1 / 0.16 / 0.01 V/step]
*ENG
[1 to 2.5 / 9.99 / 0.01 /step]
*ENG
These are parameters for calculating the
charge bias referring to the development
*ENG
bias at process control.
[-1000 to 1000 / 0 / 1 /step]
*ENG
DC charge bias = Development bias x (1 +
*ENG
0.001 x these vales) + SP3-241-005 to -008
*ENG
These are additional values for calculating
the charge bias referring to the
*ENG
development bias at process control.
[0 to 255 / 158 / 1 V/step]
*ENG
DC charge bias = Development bias x (1 +
0.001 x SP3-241-001 to -004) + these
*ENG
values
8-199