Ricoh M065 Service Manual page 657

Gestetner, lanier, savin
Table of Contents

Advertisement

5816
[NRS Function]
I/F Setting
Selects the remote service setting.
[0 to 2 / 2 / 1 /step]
001
0: Remote service off
1: CSS remote service on
2: @Remote service on
CE Call
Performs the CE Call at the start or end of the service.
[0 or 1 / 0 / 1 /step]
002
0: Start of the service
1: End of the service
NOTE: This SP is activated only when SP 5816-001 is set to "2".
Function Flag
Enables or disables the remote service function.
[0 to 1 / 0 / 1 /step]
003
0: Disabled, 1: Enabled
NOTE: This SP setting is changed to "1" after @Remote registor has been
completed.
SSL Disable
Uses or does not use the RCG certification by SSL when calling the RCG.
007
[0 to 1 / 0 / 1 /step]
0: Uses the RCG certification
1: Does no use the RCG certification
SM Appendix
*CTL
-
8-247
System Service Mode