System Service Mode
RCG Connect Timeout
008
Specifies the connect timeout interval when calling the RCG.
[1 to 90 / 10 / 1 second /step]
RCG Write Timeout
009
Specifies the write timeout interval when calling the RCG.
[1 to 100 / 60 / 1 second /step]
RCG Read Timeout
010
Specifies the read timeout interval when calling the RCG.
[1 to 100 / 60 / 1 second /step]
Port 80 Enable
Enables/disables access via port 80 to the SOAP method.
011
[0 or 1 / 0 / – ]
0: Disabled, 1: Enabled
RFU (Remote Frimware Update) Timing
Selects the RFU timing.
013
[0 or 1 / 1 / – ]
0: RFU is executed whenever update request is received.
1: RFU is executed only when the machine is in the sleep mode.
Function Flag
This SP displays the Embedded RC Gate installation end flag.
021
0: Installation not completed
1: Installation completed
Install Status
This SP displays the Embedded RC Gate installation status.
022
0: RCG device not registered
1: RCG device registered
2: Device registered
M065/M066
8-248
SM Appendix