System Service Mode
013 Alone Time
014 Coefficient of Correction
2015
[Charge AC Adj: Result]
001 Bk
002 C
003 M
004 Y
[Color Regist Adust]
These values are the parameters for the automatic line position adjustment
and are adjusted at the factory. However, you must input a value for
2101
SP2101-001 after replacing the laser unit. For details, see "Laser Unit" in the
"Replacement and Adjustment" section. The value should be provided with the
new laser unit.
001 Bk: Main Scan: Dot
002 C Main Scan: Dot
003 M Main Scan: Dot
004 Y Main Scan: Dot
005 Bk: Sub Scan: Line
006 C: Sub Scan: Line
007 M: Sub Scan: Line
008 Y: Sub Scan: Line
M065/M066
*ENG
[0 to 1440 / 360 / 10 min/step]
*ENG
[0 to 2 / 1 / 0.01 kV/mA/step]
*ENG
*ENG
[0 to 9 / 0 / 1 /step]
*ENG
*ENG
*ENG
*ENG
[–511 to 511 / 0 / 1 dot/step]
*ENG
*ENG
*ENG
*ENG
[–800 to 800 / 0 / 1 line/step]
*ENG
*ENG