6.2.1.12 CONFIG: Remote (Remote Control)
Remote Control=Local
Use the
arrow keys to select Local, Serial remote, or Ethernet, and then press ENTER.
▲▼
If selecting Local, then reconfiguration via Serial Remote or Ethernet is not permitted although
remote monitoring is still possible. If Local or Serial Remote selected, a typical submenu is
displayed – proceed to the next section.
6.2.1.12.1 CONFIG: Remote Local or Serial remote settings
Interface= RS-485-4W
Address= 0001
If selecting either Local or Serial remote control, use the
Address, or Baudrate; then, use the
each digit of the Address. Note the following:
•
Character format is not selectable and is fixed at 8-N-1.
•
For RS-485 (aka EIA-485) – The permitted address range is from 0001 to 9999. Address
0000 is reserved for universal addressing.
•
For RS-232 (aka EIA-232): The Address is fixed at 0000.
6.2.1.13 CONFIG: IP
IP Config: Addresses
arrow keys to select Addresses, SNMP, Setup, ANT, AccessList, or – displayed only
Use the
◄ ►
when the optional IP Packet Processor card is installed – PktP-Enable, and then press ENTER.
6.2.1.13.1 CONFIG: IP Addresses
IP Addresses:
Addr/Range
Use the
◄ ►
arrow keys to select MAC, Gateway, or Addr/Range, and then press ENTER.
(Local,Serial remote,Ethernet)
▲▼
ANT
AccessList
(232,485-2,485-4)
9600 baud
◄ ►
arrow keys to edit the Interface type, Baudrate, and
SNMP
Setup
PktP-Enable
MAC
Gateway
6–52