Comtech EF Data CDM-625A Installation And Operation Manual page 319

Advanced satellite modem (18 kbps – 25 mbps)
Hide thumbs Also See for CDM-625A:
Table of Contents

Advertisement

CDM-625A Advanced Satellite Modem
Serial-based Remote Product Management
Command
Parameter
Number of
(Instruction
Type
Arguments
& Qualifier)
Rx BERT
RBP=
1 byte
Pattern
BERT 10E-3
BKE=
1 byte, value of 0
Error Insert
or 1
BERT Restart
BRM=
None
Monitor
BERT Result in
N/A
7 bytes, numeric
bit errors
BERT Result in
N/A
6 bytes
average BER
Description of Arguments
Command or Query.
Rx BERT Pattern, in the form x, where:
0=space
1=mark
2=1:1
3=1:2
4=63
5=511
6=2047 (default)
7=2047R (or 2047 Alternate)
8=Mil-188
9=2^15-1
A=2^20-1
B=2^23-1
Example: RBP=6 (Rx BERT Pattern is 2047)
Command or Query.
Inserts 10E-3 BER in the form x, where:
x = 0 (Off) or 1 (On)
Example: BKE=1
Command only.
Example: BRM=
Note: This command takes no arguments.
Query only.
BERT monitor results in bit errors. If bit errors exceed 9999999, then BRE=9999999.
Query only
Returns the value of the average BER in the form a.b x 10-c. First 3 bytes are the value. Byte 5 is the exponent. Last byte
is the indicator of Sync Loss. A '*' in last byte means there was a loss of pattern synchronization since last restart, but
now is synchronized. A '_' (space) in last byte means pattern synchronization is achieved.
Returns 999999 if there's no sync in BERT monitor.
Example 1: BRR=2.8E7 (BER is 2.8 x 10
, and in sync)
-7
Example 2: BRR=3.4E5* (BER is 3.4 x 10
, and there was a Sync Loss)
-5
8–37
Revision 0
MN-CDM625A
Query
Response to
(Instruction &
Response to Query
Command
Qualifier)
RBP=
RBP?
RBP=x
RBP?
(see Description of
RBP#
Arguments)
BKE=
BKE?
BKE=x
BKE?
(see Description of
BKE#
Arguments)
BRM=
N/A
N/A
N/A
BRE?
BRE=xxxxxxx
N/A
BRR?
BRR=a.bEcx