CDM-625A Advanced Satellite Modem
CDM-625A ODU (Transceiver, BUC, LNB) Operation
•
By using the CDM-625A Telnet Command Line Interface for CSAT-5060 Transceiver
operation (excluding the KST-2000A/B Transceiver or the LPOD).
10.2
ODU Remote Control Address Setup
The ODU, as connected to a CDM-625A through FSK (Frequency Shift Keying), can be remotely
monitored and controlled through the use of ODU commands and queries issued via serial
remote control or with the Telnet Command Line Interface (CLI).
The address of the ODU is set up as follows:
•
For Local-End ODUs:
o Use the Modem's RC Address + 1 for a Standalone Unit or the Online Unit in a 1:1
Redundancy System;
o Use the Modem's RC Address + 2 for the Offline Unit in a 1:1 Redundancy System.
•
For Distant-End ODUs in an EDMAC setup:
o Use the EDMAC Slave Address (ESA) Range +4 for Standalone Unit or the Online Unit
in a 1:1 Redundancy System;
o Use the EDMAC Slave Address (ESA) Range +5 for the Offline Unit in a 1:1
Redundancy System.
•
Chapter 8. SERIAL-BASED REMOTE PRODUCT MANAGEMENT
•
Appendix H. EDMAC CHANNEL
10–2
Revision 0
MN-CDM625A