Turning Off The Power; Limited Down Time - Acopia Adaptive Resource Switch Cli Maintenance Manual

Table of Contents

Advertisement

Contact Acopia support if your output does not match the above NVR Battery and ECC
State.

Turning Off the Power

Limited Down Time

CLI Maintenance Guide
Good
No Error
bstnA6kB#
By this time, all ARX clients should be aware of the impending service outage.
In a redundant pair, turn the power off at the backup switch first, then the active
switch. Press the power button or flip the power switch(es) on the chassis. These are
located in different places on each platform:
ARX®500 - a button on the right side of the front panel (see the
Hardware Installation
ARX®1000 - a switch on the back panel (see the
Installation
Guide).
ARX®6000 - one switch per power supply, on the bottom of the back panel (see
the
ARX®6000 Hardware Installation
As mentioned above, the NVRAM battery drains in 72 hours. If you do not restore
power in that time, all managed volumes will re-import their back-end shares after
you power on. Depending on the size of the directory trees in these shares, import can
be a time-consuming process.
256
Guide).
Guide).
Powering Down the ARX
Turning Off the Power