Troubleshooting Managed Volumes
Correcting Share-Import Errors
Table 8-1. Share Status Conditions (Continued)
Status Condition
Error: Export In Use By Another
Switch
Error: Export is read-only, cannot
import.
Error: Failed to Contact Filer.
Error: Failed to contact filer for
attribute lookup.
Error: Failed to contact portmap
service during import scan.
8-32
Description/Action
The filer share contains a hidden directory, .acopia, written by a
different ARX. Two ARXes cannot import the same share. If the
share is not imported by another switch anymore, remove the
directory manually and re-import.
If this happens to all shares after a switch replacement, the old
switch's UUID was not properly applied to the replacement
switch. Consult the appropriate Hardware Installation manual
for switch-replacement instructions.
Check the share configuration at the filer: the ARX requires
read/write access throughout the share's directory tree.
he back-end device could not be located with the IP address
T
configured for the filer. From gbl-ext-filer mode, use the
command to reset the filer's address.
address
Use the
command and/or
show exports
connection to the filer.
(NFS) These errors indicate an NFS-server problem at the filer.
ip
to check the
ping