Acopia Adaptive Resource Switch Cli Maintenance Manual page 147

Table of Contents

Advertisement

Troubleshooting Tools
Accessing the Syslog
For example, this command shows the contents of the active syslog:
bstnA6k(cfg)# show logs syslog
SWITCH:2004-05-06T06:24:52.386-0400:1-scm-905:SCM_CLI-0-6(I)-CLI_COMMAND:User
admin: Command: SWITCH# del report
SWITCH:2004-05-06T06:24:53.136-0400:1-scm-905:SCM_CLI-0-6(I)-CLI_COMMAND:User
admin: Command: SWITCH# slot reload
SWITCH:2004-05-06T06:24:53.161-0400:1-scm-643:CHASS_NEW-0-7(D)-MSG7:slot_cmd_1_s
vc SLOT_CMD_RELOAD: begin
SWITCH:2004-05-06T06:24:53.206-0400:1-scm-643:CHASS_NEW-0-7(D)-MSG7:Post Event
type=CHASSIS, state=DOWN-REQ, shelf=0x1800, slot=0, mod=0x0, proc=0.
sm-3-2:init: Switching to runlevel: 6
sm-3-1:init: Switching to runlevel: 6
sm-3-2:2004-05-06T06:24:53.362-0400:3-apm-277:LOGMGRD-0-6(I)-MSG6:Version
0.12.0.4649 (May 05 2004 02:19:30) [nbuilds] (build 4649) shutting down
sm-3-1:2004-05-06T06:24:53.460-0400:3-apm-277:LOGMGRD-0-6(I)-MSG6:Version
0.12.0.4649 (May 05 2004 02:19:30) [nbuilds] (build 4649) shutting down
SWITCH:2004-05-06T06:24:53.718-0400:1-scm-825:SCM_L2SW_DRV-0-7(D)-MSG7:** Port
6: link down [slot=1,unit=1]
SWITCH:2004-05-06T06:24:54.196-0400:1-scm-864:SCM_L2SW_DRV-0-7(D)-MSG7:soc_schan
_op: operation timed out [slot=5]
SWITCH:2004-05-06T06:24:54.386-0400:1-scm-1183:SCM_TEMSTATS-0-7(D)-MSG7:TEMRingB
ufferPoll() - SSB Error 5 TEMCoreID 180051 Addr (60ff0228) size 7
SWITCH:2004-05-06T06:24:54.386-0400:1-scm-1183:SCM_TEMSTATS-0-7(D)-MSG7:TEMRingB
ufferPoll() - SSB Error 5 TEMCoreID 180052 Addr (60ff1228) size 7
SWITCH:2004-05-06T06:24:54.387-0400:1-scm-1183:SCM_TEMSTATS-0-7(D)-MSG7:TEMRingB
ufferPoll() - SSB Error 5 TEMCoreID 180053 Addr (42ff0228) size 7
SWITCH:2004-05-06T06:24:54.387-0400:1-scm-1183:SCM_TEMSTATS-0-7(D)-MSG7:TEMRingB
ufferPoll() - SSB Error 5 TEMCoreID 180054 Addr (42ff1228) size 7
SWITCH:2004-05-06T06:24:54.387-0400:1-scm-1183:SCM_TEMSTATS-0-7(D)-MSG7:TEMRingB
ufferPoll() - SSB Error 5 TEMCoreID 180055 Addr (44ff0228) size 7
SWITCH:2004-05-06T06:24:54.387-0400:1-scm-1183:SCM_TEMSTATS-0-7(D)-MSG7:TEMRingB
ufferPoll() - SSB Error 5 TEMCoreID 180056 Addr (44ff1228) size 7
SWITCH:2004-05-06T06:24:54.746-0400:1-scm-864:SCM_L2SW_DRV-0-7(D)-MSG7:soc_schan
_op: operation timed out [slot=5]
SWITCH:2004-05-06T06:24:55.296-0400:1-scm-864:SCM_L2SW_DRV-0-7(D)-MSG7:soc_schan
_op: operation timed out [slot=5]
SWITCH:2004-05-06T06:24:55.566-0400:1-scm-1212:SCM_TEMSTATS-0-7(D)-MSG7:TEMReadO
nlyStatsPoll() - SSB Error 5 TEMCoreID 180051 Addr (60045820) size 30
--MORE--
CLI Maintenance Guide
6-19

Advertisement

Table of Contents
loading

Related Products for Acopia Adaptive Resource Switch

Table of Contents