Sensor (Fuser Exit) Miscellaneous Jam Service Check; Fuser Id Chip Control Jam Service Check - Lexmark MS81x Service Manual

Machine type 4063-2xx, -4x0, -63x, -83x
Hide thumbs Also See for MS81x:
Table of Contents

Advertisement

Sensor (fuser exit) miscellaneous jam service check

Action
Step 1
Check the sensor (fuser exit) for proper operation.
a
Enter the diagnostic mode.
b
Select Base sensor test.
c
Observe the line item fuser exit.
Does the display on the control panel change every time the sensing area
of the above sensor is interrupted or blocked?
Step 2
Check the above sensor for proper connection.
Is the above sensor connected properly?
Step 3
Perform a print test.
Does the problem remain?

Fuser ID chip control jam service check

Action
Step 1
Ensure the fuser is properly installed.
Is the fuser properly installed?
Step 2
Remove the existing fuser, and install a different fuser.
Does the error remain?
Step 3
Ensure the cable for socket "J27" on the controller board is properly
connected.
Is the above connection properly connected?
Step 4
Ensure the LVPS connections are properly connected.
Are the above connections properly connected?
Step 5
Reset the machine.
Does the error continue?
Yes
Go to
Replace the fuser. See
"Fuser removal" on
page
Contact the next level
of technical support.
Yes
Go to step 2.
Replace the fuser. See
"Fuser removal" on
page
Go to step 3.
Go to step 4.
Go to step 5.
Replace the LVPS. Go to
"LVPS removal" on
page
Go to step 6.
Diagnostic information
68
No
step
3.
Go to step 2.
Reseat the connection.
322.
Problem solved.
No
Reinstall the fuser.
Problem solved.
322.
Reseat the connection.
Reseat the
connections.
Problem solved.
366.
4063

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ms71x

Table of Contents