Cartridge cooling fan service check
Action
Step 1
Ensure the cable for socket "HVPS" on the controller board is properly
connected.
Is the above connection properly connected?
Step 2
Reset the machine.
Does the error continue?
Step 3
Reset the machine.
Does the error continue?
LVPS cooling fan service check
Action
Step 1
Ensure the LVPS cooling fan cable is properly connected.
Is the above cable properly connected?
Step 2
Reset the machine.
Does the error continue?
Step 3
Reset the machine.
Does the error continue?
Yes
Go to step 2.
Replace the cartridge
cooling fan with cable.
See
fan removal" on
page
Go to step 3.
Replace the controller
board. See
board removal" on
page
Yes
Go to step 2.
Replace the LVPS fan
with cable.
Go to step 3.
Replace the controller
board. See
board removal" on
page
Diagnostic information
112
No
Reseat the connection.
Problem resolved.
"Cartridge cooling
363.
Problem resolved.
"Controller
349.
No
Reseat the connection.
Problem resolved.
Problem resolved.
"Controller
349.
4063