Redrive motor service check

Action
Step 1
Ensure the cable for socket "REDRIVE" on the controller board is properly
connected.
Is the above connection properly connected?
Step 2
Reset the machine.
Does the error continue?
Step 3
Reset the machine.
Does the error continue?

Duplex motor service check

Action
Step 1
Ensure the cable for socket "DUPLEX MTR" on the controller board is
properly connected.
Is the above connection properly connected?
Step 2
Reset the machine.
Does the error continue?
Step 3
Reset the machine.
Does the error continue?
Yes
Go to step 2.
Replace the upper
redrive. See
redrive removal" on
page
Go to step 3.
Replace the controller
board. See
board removal" on
page
Yes
Go to step 2.
Replace the duplex
motor. See
motor removal" on
page
Go to
Replace the controller
board. See
board removal" on
page
Diagnostic information
110
No
Reseat the connection.
Problem resolved.
"Upper
331.
Problem resolved.
"Controller
349.
No
Reseat the connection.
Problem resolved.
"Duplex
320.
step
3.
Problem resolved.
"Controller
349.