14
Remove the screw (B) securing the grounding wire to the media aligner roller.
15
Locate the adjuster screw access hole in the controller board shield.
Note: The adjuster screw is contained between the left frame and the drive plate; it will stay in place during
media aligner roller replacement. If the adjuster screw needs to be replaced, then the controller board and the
main drive motor will also have to be removed to access the adjuster screw.
16
Using a 3mm hex wrench, completely loosen the adjuster screw (C) counterclockwise, as shown in the following
image.
Installation warning: Make sure to reattach the grounding strap to the correct screw, and make sure the
grounding strap is out of the paper path.
Repair information