KEYLESS CONTROL MODULE INSPECTION [WITHOUT ADVANCED KEYLESS
ENTRY AND START SYSTEM ]
1. Measure the voltage or inspect for continuity according to the Terminal Voltage Table
(Reference).
If the voltage is not as specified in the Terminal Voltage Table (Reference),
inspect the parts under "Inspection item(s)".
2. If the system does not work properly even though the parts or related wiring harnesses do not
have any malfunction, perform symptom troubleshooting.
Terminal Voltage Table (Reference)
Terminal Signal name
1A
Power supply D.LOCK 30 A fuse
Measurement
Connected to
Under any
condition
Within 5 min
Voltage
condition
(V)/Continuity
B+
Inspection item(s)
D.LOCK 30 A
fuse
Battery
Inspect
related
harness.
ROOM 15 A