Appendix B Technical Specifications
Environmental Specifications
MX8
Feature
Operating Temperature
Storage Temperature
Water and Dust
Operating Humidity
Standards
Contamination
Vibration
ESD
AC Wall Adapter
Feature
Input Power Switch
Power "ON" Indicator
Input Fusing
Input Voltage
Input Frequency
Input Connector
Output Connector
Output Voltage
Output Current
Operating Temperature
Storage Temperature
Humidity
E-EQ-MX8RG-A
Specification
14°F to 122°F (-10°C to 50°C)
-4°F to 158°F (-20°C to 70°C)
IP54
Up to 90% non-condensing at 104°F (40°C)
See "MX8 User's Guide", Appendix B.
Resistant to exposure to skin oil and other lubricants.
Based on MIL Std 810D
8 kV air, 4kV direct contact
Specification
None
None
Current Fuse
100VAC min – 240 VAC max
50 - 60 Hz
North American wall plug, no ground
AC wall adapter has a 5.5mm barrel connector. This connects to the
LXE cables which transition power to the 20 pin D connector.
+5V, regulated
0 Amps min, 3 Amps max
32 F to 100° F / -0° C to 40° C
The LXE-approved AC Power Adapter is only intended for use in a
25°C (77°F) maximum ambient temperature environment.
-40° F to 180° F / -40° C to 80° C
(fahrenheit degrees (temperature) = ((centigrade temperature)*9/5)+32)
Operates in a relative humidity of 5 – 95% (non-condensing)
255
MX8 Reference Guide