Mounting
Figure 1: XTi chassis and trim ring
D
To mount the panel on a wall:
1.
Lay the panel flat on a table.
2.
Remove trim ring (B in Figure 1 above) from panel by lifting at
notch (C in Figure 1 above).
3.
Separate the panel chassis from the mounting plate by lifting
up on the tabs (A in Figure 1 above) and swinging the chassis
open.
4.
Choose a panel location.
5.
Run all necessary power, phone, siren, and hardwired contact
wires to the desired panel location.
When choosing the AC outlet location for the AC power
transformer, make sure the outlet is not controlled by a
switch or that it is not part of a ground fault circuit interrupt
(GFCI).
6.
Hold the mounting plate against the wall and mark the
mounting hole locations (Figure 2 below) with a pencil.
Note: Mark both mounting holes in the middle of the
mounting slot. This will allow better adjustment of the panel
before securing it to the wall.
2
A
Figure 2: Mounting holes
B
C
7.
Secure the mounting screws (provided) to the locations on the
wall marked in step 6. Do not tighten the screws. Leave
enough clearance to mount the mounting plate.
Note: Use wall anchors if no studs are present.
8.
Mount the mounting plate to the wall. Insert the top mounting
hole first, then the bottom hole. Adjust the fit to make sure the
mounting plate is level. Hold the mounting plate in place and
tighten the screws.
9.
Hang the panel chassis on the mounting plate at the plastic
hinges, swing the chassis up to the mounting plate and
engage at the tabs (A in Figure 1 above).
10. Reattach the trim ring.

Connecting hardwired devices

The panel has five screw terminals, two battery terminals, and two
telephone connections. The screw terminals connect the AC
power, sirens, and/or hardwired detectors.
Figure 3: Wiring terminals
Program sensors and devices before you install them. Follow the
instructions in "Sensors" on page 7 to add the sensors to panel
memory.
The HW1 I/O terminal is dual purpose and can be used for either
siren or hardwired contact connections. The HW2 in terminal is an
input only.
Mounting hole