How To Install The Server Into The Rack - Oracle Sun Fire X2270 M2 Service Manual

Hide thumbs Also See for Sun Fire X2270 M2:
Table of Contents

Advertisement

Set the server on a flat stable surface.
10
If necessary, push the extended rails into the rack.
11
"How to Install the Server Into the Rack" on page 23
See Also
"How to Remove the Server Cover" on page 25
Next Steps

How to Install the Server Into the Rack

Use this procedure to install the server chassis, with mounting brackets, into the slide rail
assemblies that are mounted to the rack.
This procedure requires a minimum of two people because of the weight of the server.
Caution –
Attempting this procedure alone could result in equipment damage or personal injury.
Always load equipment into a rack from the bottom up so that it does not become
Caution –
top-heavy and tip over. Deploy your rack's anti-tilt bar to prevent the rack from tipping during
equipment installation.
Ensure that the slide rails and the slide rail assemblies are fully collapsed into the rack.
1
Push the slide rails into the slide rail assemblies and then collapse the assemblies.
Tools and Supplies Needed
23