Replacing the Front I/O Board (FRU)
▼
How to Install the I/O Board
See:
Before You Begin
"Locations of Internal Server Components" on page 30
Position the I/O board on top of the HD cage with the connectors facing upward.
1
Connect the I/O cable to the connector I/O board.
2
Lower the board onto the server and slide the two connectors on the front of the board under
3
the front edge of the server.
Align the screw holes in the board with the threaded standoffs.
4
To secure the board to the server, fully tighten the three screws.
5
Install the air duct. See
6
Prepare the server for operation. See
7
"How to Remove the I/O Board" on page 64
See Also
66
Sun Fire X2270 M2 Server Service Manual • January, 2012, –12
"How to Install the Air Duct"on page
"How to Prepare for Operation"on page
53.