Oracle Sun Fire X2270 M2 Service Manual page 36

Hide thumbs Also See for Sun Fire X2270 M2:
Table of Contents

Advertisement

Error Correction and Parity
Ensure that the DIMM is correctly installed in the slot.
8
Install the air duct. See
9
Prepare the server for operation. See
10
"How to Remove a DIMM" on page 33
See Also
"Error Correction and Parity" on page 36
"DIMM Slot Designations" on page 37
"DIMM Population Rules" on page 38
"Removing and Installing DIMMs (CRU)" on page 33
Error Correction and Parity
The server's processor provides parity protection on its internal cache memories and
error-correcting code (ECC) protection of the data. The system can detect and log to the system
event log the following types of errors:
Correctable and uncorrectable memory ECC errors
Correctable and uncorrectable CPU internal errors
Advanced ECC corrects up to 4 bits in error on nibble boundaries, if they are all in the same
DRAM. If a DRAM fails, the DIMM continues to function.
Refer to the Oracle Integrated Lights Out Manager 3.0 User's Guide for information about how to
access the error log.
36
Sun Fire X2270 M2 Server Service Manual • January, 2012, –12
"How to Install the Air Duct"on page
"How to Prepare for Operation"on page
53.