Click Enter Upgrade Mode.
6
A dialog box appears asking you to confirm to enter Upgrade mode.
Click OK to enter Upgrade mode or Cancel to exit the process.
7
ILOM stops its normal operation and prepares for a flash upgrade.
Enter the path to the new ILOM flash image file in the Select Image File to Upload field or click
8
Browse to locate and select the firmware update file.
Use files with .pkg extensions.
Click Upload to upload the file, or click Cancel to exit the process.
9
The selected file is uploaded and verified as the correct image update for your SP.
This process takes about one minute with a fast network connection.
When the Verify Firmware Image page appears, click OK.
10
Select Preserve Configuration to keep your ILOM settings. If not, the settings are overwritten by
11
the firmware defaults.
Click Start Upgrade or click Cancel to exit the process.
12
When you click Start Upgrade, a progress screen indicates that the firmware image is being
updated. When the update progress reaches 100%, the firmware update is complete.
When the update is complete, the system automatically reboots.
After the SP finishes rebooting, use your browser to reconnect to ILOM.
13
Recovering the SP and BIOS Firmware
If your server has corrupted SP or BIOS firmware, you can use one of the following methods to
recover the firmware:
"How to Recover the SP and BIOS Firmware Using a CD/DVD Drive" on page 92
"How to Recover the SP and BIOS Firmware Using a USB Flash Drive" on page 92
You should only use the following procedures for system recovery, as these procedures
Note –
will not preserve BIOS settings and ILOM configurations.
Recovering the SP and BIOS Firmware
91