Oracle Sun Fire X2270 M2 Service Manual page 26

Hide thumbs Also See for Sun Fire X2270 M2:
Table of Contents

Advertisement

Tools and Supplies Needed
How to Install the Server Cover
Orient the cover over the server so the lip edge of the cover is at the front of the server and the
1
captive retaining screw is at the rear.
Set the cover on top of the server and position it so approximately .5 inch of the cover extends
2
over the rear of the server.
Use the indent on the top cover to push the cover toward the front of the server until the captive
3
screw is in position.
To secure the cover, tighten the captive screw.
4
"How to Install the Server Into the Rack" on page 23
Next Steps
How to Prepare for Operation
Ensure that all new components are installed as described in the component replacement
1
instructions (see
Ensure that all existing components are properly seated and connected.
2
Ensure that all internal cabling is connected and secured within the server and that the cabling
3
is not obstructing the air flow.
Inspect the interior of the server and remove any tools and loose or foreign debris.
4
Use a vacuum, compressed air, or an antistatic brush to clean the interior of the server so
5
component surfaces and server air vents are free of dust.
Caution –
the server. Liquid has the potential for causing shorts in electrical systems.
Install the system's cover. See
6
Install the server in the rack. See
7
Connect all external cables to the system.
8
To apply AC power, connect the AC power cords to the server.
9
When the AC power is applied, the server enters standby mode.
26
Sun Fire X2270 M2 Server Service Manual • January, 2012, –12
"Component Replacement Procedures and Topic"on page
Potential for component damage. Do not use liquid or aerosol spray cleaners to clean
"How to Install the Server Cover"on page
"How to Install the Server Into the Rack"on page
29).
26.