Oracle Sun Fire X2270 M2 Service Manual page 87

Hide thumbs Also See for Sun Fire X2270 M2:
Table of Contents

Advertisement

BIOS POST Error Message
Password check failed
Keyboard/Interface Error
S.M.A.R.T. error on the drive
BIOS POST Memory Testing Sequence
The BIOS POST memory testing sequence is performed as follows:
1. The first megabyte of DRAM is tested by the BIOS before the BIOS code is shadowed (that
is, copied from ROM to DRAM).
2. After executing out of DRAM, the BIOS performs a simple memory test (where a write/read
of every location with the pattern 55aa55aa is performed).
Note –
Settings Configuration screen. Enabling Quick Boot causes the BIOS to skip the memory
test.
3. The BIOS polls the memory controllers for both correctable and non-correctable memory
errors and logs those errors into the SP.
4. The message BMC Responding appears at the end of the POST.
The simple memory test is performed only if Quick Boot is not enabled from the Boot
Error Type
Resolution
Password
Press F1 to continue.
check error
Check the SP event log in ILOM for more details.
Note –
entered does not match the password specified in
the BIOS Setup utility. This condition might
occur for both Supervisor and User password
verification.
Keyboard
Press F1 to continue.
controller error
Check the SP event log in ILOM for more details.
Note –
Controller failure. This error might indicate a
problem with the system hardware.
S.M.A.R.T.
Press F1 to continue.
device error
Check the SP event log in ILOM for more details.
Note –
indicate to replace the storage device.
BIOS POST Memory Testing Sequence
This type of error indicates a password
This type of error indicates a Keyboard
S.M.A.R.T. failure messages might
87