Recovering the SP and BIOS Firmware
How to Recover the SP and BIOS Firmware Using a
CD/DVD Drive
Insert the Tools and Drivers CD into the CD/DVD drive.
1
Reboot the server.
2
When the Tools and Drivers CD menu appears, select menu option 3, Exit to DOS.
3
From the DOS prompt, navigate to the directory on the Tools and Drivers CD that contains the
4
recovery program.
For example:
-> cd firmware/BIOS
From the DOS prompt, type the following command to run the recovery program:
5
-> run flash.bat
When the Recovery menu is appears, select menu option 1.
6
For example:
1) Flash System BIOS firmware - Clear BIOS CMOS and load defaults.
Note –
might need to reset some of the ILOM and BIOS settings.
When the recovery program is completed, disconnect the AC power connection from the server
7
for 30 seconds, then reconnect the AC power.
How to Recover the SP and BIOS Firmware Using a USB
Flash Drive
Create a bootable MS-DOS USB flash drive.
1
You can create a bootable USB flash drive using a freeware application such as BootFlashDOS
1.0.
Using a system that contains both a CD/DVD drive and a USB port, insert the Tools and Drivers
2
CD into the CD/DVD drive and the bootable USB flash drive into an available USB port.
Copy the contents of the /firmware/USBFlash/SPREcovery/* directory from the Tools and
3
Drivers CD to a bootable MS-DOS USB flash drive.
92
Sun Fire X2270 M2 Server Service Manual • January, 2012, –12
When you select option 1, the default ILOM and BIOS settings are loaded. Therefore, you