Motorola RFS7000 Series System Reference Manual page 437

Rf switch
Hide thumbs Also See for RFS7000 Series:
Table of Contents

Advertisement

1. Select
Diagnostics
>
2. Refer to the following information displayed within the Configuration tab:
Description
Destination IP
Timeout (sec)
No. of Probes
Frequency
3. To edit the properties of an existing ping test, select a ping based on the description listed and click
the
Edit
button. For more information, see
Modifying the Configuration of an Existing Ping Test on page
4. Select an existing ping test from those displayed within the Configure tab and click the
to remove the ping test from those displayed.
5. Click the
Add
button to display a screen used to define the attributes of a new ping test. For more
information, see
Adding a New Ping Test on page
Ping
from the main menu.
Displays the user assigned description of the ping test. The name is
read-only. Use this title to determine whether this test can be used
as is or if a new ping test is required.
Displays the IP address of the target device. This is the numeric
destination for the device sent the ping packets. If this address
does not accurately reflect the ping destination target, the ping test
will not be successful.
Displays the timeout value (in seconds) used to timeout the ping
test if a round trip packet is not received from the target device.
Displays the number of packets transmitted to the target IP address
to discern the round trip time between the switch and its connected
device.
Define the interval (in seconds) between ping packet
transmissions. Define a longer interval if high levels of network
congestion are anticipated between the switch and its target
device. Use a value of 0 to execute a single ping test or stop a
currently executing ping test.
8-22.
8-23.
8-21
Diagnostics
Delete
button

Advertisement

Table of Contents
loading