IMPORTANT
Use care when changing the Global Memory Adjust option. Increasing
the amount of global memory with the Global Memory Adjust option
reduces the amount of page memory. In turn, reducing the amount of
page memory too much can significantly reduce the throughput of the
printer.

Printer Control Menu

Printer Control
Surface Volts
Default is 580.
*
Default is 340.
*
Range is 500
Range is 200
through 700 volts,
through 600 volts,
in increments of 4.
in increments of 10.
Cut-Sheet
Y Adj.
*
Default is 0/100".
(See Note 1.)
Range is -100/100"
through +100/100", in
increments of 1/100".
Note 1:
Bias Volts
LED Time
*
Default is 00%.
Range is -32%
through +32%
in increments
of 0.25%.
Fan-Fold
X Adj.
*
Default is 0/100".
*
(See Note 1.)
Range is -100/100"
through +100/100", in
increments of 1/100".
Figure I–11. Printer Control Menu
Printer Control Menu
Default values will vary depending on the
factory settings on the inspection sheet
inside the printer. If there is no inspection
sheet, locate the serial number of the printer
and contact Printronix for the factory-set value.
Cut-Sheet
LED Factory
X Adj.
*
Default is 25%.
*
Default is 0/100".
(See Note 1.)
Range is 0.25%
through 50%
Range is -100/100"
in increments
through +100/100", in
of 0.25%.
increments of 1/100".
Fan-Fold
Y Adj.
Default is 0/100".
*
Press ENTER to
(See Note 1.)
reset the stacker
swinger to its initial
Range is -100/100"
(powerup) position.
through +100/100", in
increments of 1/100".
Press UP, DOWN, NEXT, and
PREV to view options.
Press ENTER to select an option.
Press ONLINE at any time to exit
configuration and save changes.
Reset
Stacker
I–105