Electromagnetic Compatibility (EMC) Standards
This product complies with and conforms to the following international
EMC standards and all relevant national deviations:
Limits and Methods of Measurement of Radio Interference of Information
Technology Equipment, CISPR 22:1997, EN55022:1998, and AS/NZS
3548.
Information Technology Equipment - Immunity Characteristics - Limits
and Methods of Measurement, CISPR 24:1997 and EN55024:1998,
including:
Electrostatic Discharge (ESD) IEC 61000-4-2
Radiated Immunity IEC 61000-4-3
Electrical Fast Transient IEC 61000-4-4
Lightning Effects IEC 61000-4-5
Conducted Immunity IEC 61000-4-6
Mains Frequency Magnetic Field IEC 61000-4-8
Voltage Dips and Variations IEC 61000-4-11
Power Line Emissions, IEC 61000-3-2: Electromagnetic compatibility
(EMC) - Part 3-2: Limits - Limits for harmonic current emissions.
Power Line Emissions, IEC 61000-3-3: Electromagnetic compatibility
(EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage
fluctuations and flicker in public low-voltage supply systems.
Federal Communications Commission Statement
Part 15:
Note: This equipment has been tested and found to comply with
the limits for a Class A digital device, pursuant to Part 15 of the
FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is
operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the instruction
manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential
area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own
expense.
Part 68: Answer-Supervision Signaling
Allowing this equipment to be operated in a manner that does not provide
proper answer-supervision signaling is in violation of Part 68 rules. This
equipment returns answer-supervision signals to the public switched
network when:
answered by the called station,
answered by the attendant, or
routed to a recorded announcement that can be administered
by the customer premises equipment (CPE) user.
This equipment returns answer-supervision signals on all direct inward
dialed (DID) calls forwarded back to the public switched telephone
network. Permissible exceptions are:
A call is unanswered.
A busy tone is received.
A reorder tone is received.
Avaya attests that this registered equipment is capable of providing users
access to interstate providers of operator services through the use of
access codes. Modification of this equipment by call aggregators to block
access dialing codes is a violation of the Telephone Operator Consumers
Act of 1990.
REN Number
For MCC1, SCC1, CMC1, G600, and G650 Media Gateways:
This equipment complies with Part 68 of the FCC rules. On either the
rear or inside the front cover of this equipment is a label that contains,
among other information, the FCC registration number, and ringer
equivalence number (REN) for this equipment. If requested, this
information must be provided to the telephone company.
For G350 and G700 Media Gateways:
This equipment complies with Part 68 of the FCC rules and the
requirements adopted by the ACTA. On the rear of this equipment is a
label that contains, among other information, a product identifier in the
format US:AAAEQ##TXXXX. The digits represented by ## are the ringer
equivalence number (REN) without a decimal point (for example, 03 is a
REN of 0.3). If requested, this number must be provided to the telephone
company.
For all media gateways:
The REN is used to determine the quantity of devices that may be
connected to the telephone line. Excessive RENs on the telephone line
may result in devices not ringing in response to an incoming call. In most,
but not all areas, the sum of RENs should not exceed 5.0. To be certain
of the number of devices that may be connected to a line, as determined
by the total RENs, contact the local telephone company.
REN is not required for some types of analog or digital facilities.
Means of Connection
Connection of this equipment to the telephone network is shown in the
following tables.
For MCC1, SCC1, CMC1, G600, and G650 Media Gateways:
Manufacturer's Port
FIC Code
Identifier
Off premises station
OL13C
DID trunk
02RV2-T
CO trunk
02GS2
02LS2
Tie trunk
TL31M
Basic Rate Interface
02IS5
1.544 digital interface
04DU9-BN
04DU9-IKN
04DU9-ISN
120A4 channel service
04DU9-DN
unit
For G350 and G700 Media Gateways:
Manufacturer's Port
FIC Code
Identifier
Ground Start CO trunk
02GS2
DID trunk
02RV2-T
Loop Start CO trunk
02LS2
1.544 digital interface
04DU9-BN
04DU9-DN
04DU9-IKN
04DU9-ISN
Basic Rate Interface
02IS5
For all media gateways:
If the terminal equipment (for example, the media server or media
gateway) causes harm to the telephone network, the telephone company
will notify you in advance that temporary discontinuance of service may
be required. But if advance notice is not practical, the telephone
company will notify the customer as soon as possible. Also, you will be
advised of your right to file a complaint with the FCC if you believe it is
necessary.
The telephone company may make changes in its facilities, equipment,
operations or procedures that could affect the operation of the
equipment. If this happens, the telephone company will provide advance
notice in order for you to make necessary modifications to maintain
uninterrupted service.
If trouble is experienced with this equipment, for repair or warranty
information, please contact the Technical Service Center at
1-800-242- 2121 or contact your local Avaya representative. If the
equipment is causing harm to the telephone network, the telephone
company may request that you disconnect the equipment until the
problem is resolved.
SOC/
Network
REN/
Jacks
A.S. Code
9.0F
RJ2GX,
RJ21X,
RJ11C
0.0B
RJ2GX,
RJ21X
0.3A
RJ21X
0.3A
RJ21X
9.0F
RJ2GX
6.0F, 6.0Y
RJ49C
6.0F
RJ48C,
RJ48M
6.0F
RJ48C,
RJ48M
6.0F
RJ48C,
RJ48M
6.0Y
RJ48C
SOC/
Network
REN/
Jacks
A.S. Code
1.0A
RJ11C
AS.0
RJ11C
0.5A
RJ11C
6.0Y
RJ48C
6.0Y
RJ48C
6.0Y
RJ48C
6.0Y
RJ48C
6.0F
RJ49C