Chassis Alarms - Cisco 12000 User Manual

V3.1.1 router manager
Table of Contents

Advertisement

Chapter 18
Fault Management

Chassis Alarms

Table 18-2
Table 18-2 Monitored Attributes for a GRP Module
Trap
Cold start
RPR+ Switchover
RPR Switchover
Redundancy Framework (RF)
Progression
Warm start
Authentication Failure
Voltage Normal
Voltage Warning
Voltage Critical
Voltage Shutdown
Voltage Not Present
Temperature Normal
Temperature Warning
Temperature Critical
Temperature Shutdown
Temperature Not Present
OL-4455-01
Informational
Normal
provides information on traps that result in alarms raised against the chassis object.
Alarm Description
Cold Start: Agent reinitializing; configuration
may have changed.
RPR+ Cold Start: Agent reinitializing;
configuration may have changed
RPR Cold Start: Agent
reinitializing;configuration may have changed
RF Notification: RF state has changed. Active
Unit: <slot-no> State: <RF-state>. Peer Unit:
<slot-no> State: <RF-state>
Warm Start: Agent reinitializing; configuration
is unaltered.
Authentication Failure
Voltage higher Chassis, normal, <value> mV
Voltage higher Chassis, warning, <value> mV
Voltage higher Chassis, critical, <value> mV
Voltage higher Chassis, shutdown, <value> mV Critical
Voltage higher Chassis, notPresent, <value> mV Informational
Slot <no>: Switch Fabric Card Hot Sensor,
normal, <value> degree celsius
Slot <no>: Switch Fabric Card Hot Sensor,
warning, <value> degree celsius
Slot <no>: Switch Fabric Card Hot Sensor,
critical, <value> degree celsius
Slot <no>: Switch Fabric Card Hot Sensor,
shutdown, <value> degree celsius
Slot <no>: Switch Fabric Card Hot Sensor,
notPresent, <value> degree celsius
Cisco 12000/10720 Router Trap Support
Severity
Major
Major
Major
Major
Major
Major
Normal
Warning
Critical
Normal
Warning
Critical
Critical
Informational
Cisco 12000/10700 v3.1.1 Router Manager User Guide
Clears
Cold start
RPR+ Switchover
RPR Switchover
Redundancy
Framework (RF)
Progression
Warm start
Authentication
Failure
Normal, Critical,
Shutdown, Warning,
NotPresent
Critical, Shutdown,
Warning, NotPresent
Critical, Shutdown,
Warning, NotPresent
Critical, Shutdown,
Warning, NotPresent
Critical, Shutdown,
Warning, NotPresent
Normal, Critical,
Shutdown, Warning,
NotPresent
Critical, Shutdown,
Warning, NotPresent
Critical, Shutdown,
Warning, NotPresent
Critical, Shutdown,
Warning, NotPresent
Critical, Shutdown,
Warning, NotPresent
18-3

Advertisement

Table of Contents
loading

This manual is also suitable for:

1070012000/10720

Table of Contents