Fault Management

Interface Alarms

Table 18-3
Table 18-3 Alarms Raised Against Interface Objects
Trap
Link down
Link up
Flow Created
Flow Lost
PVC Failed
Table 18-4 Alarms Raised Against SRP Side Interface Objects for Wrap Status
Trap
SRP Ring Wrapped
SRP Ring Restored

Syslog Traps

Note
Care should be taken when using the Syslog alarm feature since there are multiple possible severity
levels that can be activated which can result in large trap volumes. This can affect Cisco 12000/10720
Router Manager performance (for example, when opening an Event Browser) and hinder effective
monitoring because of the high numbers of alarms that will be raised. It is advised that only the high
severity traps are monitored by default, switching on others if more information is required.
Cisco IOS can be configured to send Syslog traps to a designated server. There are eight levels of Syslog
information which are mapped into four categories of Cisco EMF alarm severity. Syslog specific data is
inserted into the Message portion of the Cisco EMF alarm. In all cases, alarms are raised against the
Chassis object.
OL-4455-01
provides information on traps that result in alarms raised against interface objects.
Alarm Description
Interface:<interface_name> Down,Operational
Status:Down, Administrative Status:Down
Reason:Administratively down
Interface:<interface_name> Up, Operational
Status:Up
A New Flow has been generated for
<rsvp-FlowIndex> from Link <interface
index>
Flow Lost for <rsvp-FlowIndex> from Link
<interface index>
Total <no_of_failed_PVCs> PVCs are not up on
ATM Interface <interface
Index>
Alarm Description
SRP Ring Wrapped
SRP Ring Restored
Table 18-5
summarizes the severity mapping between trap and alarm:
Cisco 12000/10720 Router Trap Support
Severity
Major
Normal
Normal
Informational
Informational
Severity
Major
Normal
Cisco 12000/10700 v3.1.1 Router Manager User Guide
Clears
Link down
Link up, link down
Flow Created, Flow
Lost
Flow Lost
PVC Failed
Clears
SRP Ring Wrapped
SRP Ring Wrapped,
SRP Ring Restored
18-5