Brocade Communications Systems MLX Series Installation Manual page 156

Mlx series, netlron xmr series
Hide thumbs Also See for MLX Series:
Table of Contents

Advertisement

2
Installing a Brocade MLXe-32 router
Follow these steps to connect a DC power source.
1. Use a #1 Phillips screwdriver to remove the screw that secures the safety cover, as shown in
FIGURE 102
2. Use a #2 Phillips screwdriver to unscrew the power lugs. Refer to
FIGURE 103
1
1
3. Crimp the correct AWG power supply wire into the power lugs.
138
Figure
102. Remove the safety cover.
Removing the safety cover (2400W power supply and 3000W power supply displayed)
Removing the power lugs (2400W power supply and 3000W power supply displayed)
Power lug screws
For 2400W power supplies: #4 AWG power supply wire
For 3000W power supplies: #2 AWG power supply wire
Refer to
Figure
104.
2
2
Power lug
Brocade MLX Series and NetIron XMR Hardware Installation Guide
Figure
103.
1
2
53-1002373-02