Brocade Communications Systems MLX Series Installation Manual page 207

Mlx series, netlron xmr series
Hide thumbs Also See for MLX Series:
Table of Contents

Advertisement

Follow these steps to connect a DC power source.
1. Use a #1 Phillips screwdriver to remove the two screws that hold the transparent cover over
FIGURE 133
1
2. Use a #2 Phillips head screwdriver to remove the power lugs.
3. Crimp #8 AWG power supply wire into the power lugs and reconnect the power lugs to the
CAUTION
For the NEBS-compliant installation of a Brocade router with AC and DC systems, use a ground
wire of at least 6 American Wire Gauge (AWG). The ground wire should have an agency-approved
crimped connector (provided with the device) attached to one end, with the other end attached to
building ground. The connector must be crimped with the proper tool, allowing it to be connected
to both ground screws on the enclosure. Before crimping the ground wire into the provided
ground lug, ensure the bare copper wire has been cleaned and antioxidant is applied to the bare
wire.
CAUTION
To ensure adequate bonding when attaching the ground lug, a minimum of 20 PSI of torque is
required to be applied to the mounting hardware used to attach the ground lug.
FIGURE 134
Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide
53-1002373-02
the power supply lugs, as shown in
Cover screws and DC power lugs
2
DC IN
Transparent cover screws
power supply unit. Refer to
Crimping the power supply wire in the power lug
Installing a Brocade MLX-16 router
Figure
133.
DC OUT ALM
1
2
Power lugs
Figure
134.
1
3
189