Final Steps; Installing A Brocade Mlx-8 Router; Preparing The Installation Site - Brocade Communications Systems MLX Series Installation Manual

Mlx series, netlron xmr series
Hide thumbs Also See for MLX Series:
Table of Contents

Advertisement

3

Installing a Brocade MLX-8 router

FIGURE 116
1
4. Connect the -48V cable to the negative terminal and the 0V cable to the positive terminal.
NOTE
DC return must be isolated from the router ground (DC-I) when connecting to DC power supplies.
5. Replace the transparent cover over the lugs.

Final steps

Complete these steps in the order listed:
Installing a Brocade MLX-8 router
This section describes how to install a Brocade MLX-8 router.

Preparing the installation site

Before installing the router, plan the location and orientation relative to other devices and
equipment. For cooling purposes, allow a minimum of six inches of space between the sides, front,
and the back of the router and walls or other obstructions. If a router is installed in a perforated
enclosure, the perforations must cover at least 60 percent of the surface.
NOTE
This equipment is suitable for installation in a Network Telecommunication facility and where NEC
requirements apply. Additionally, it may be installed in either a Common Bonding Network (CBN) or
Isolated Bonding Network (IBN). It is not intended for Outside Plant (OSP) installations.
Ensure that the proper cabling is installed at the site.
For information on cabling, refer to
"Attaching a management station"
on page 317.
164
Crimping the power supply wire in the lug
1
#8 AWG power supply wire
"Attaching a management station"
"Activating the power source"
"Verifying proper operation"
Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide53-1002373-02
"Installing Brocade MLX-8 router power supplies"
on page 227, and
"Connecting the router to a network device"
on page 170,