Brocade Communications Systems MLX Series Installation Manual page 36

Mlx series, netlron xmr series
Hide thumbs Also See for MLX Series:
Table of Contents

Advertisement

1
Router modules
TABLE 1
Part number
BR-MLX-32-MR2-M (MR2)
BR-MLX-32-MR2-X
The management module controls the hardware components, runs the networking protocols, and
provides the Real Time Operating System (RTOS).
Each router requires one management module, and can accommodate a second module for
redundancy. A redundant management module works in conjunction with the active management
module. If the active module becomes unavailable, the redundant management module
automatically takes over the system operation, minimizing system downtime. For information about
the redundancy feature, refer to the "Using a Redundant Management Module" chapter in the
Brocade MLX Series and Brocade NetIron Family Configuration Guide.
Management modules are installed in dedicated slots marked M1 and M2. By default, the module
installed in slot M1 is the active management module.
Management modules are hot-swappable, which means you can remove and replace them without
powering down the system.
NOTE
MR and MR2 management modules cannot be mixed in the same chassis.
NOTE
Prior to installing or replacing the MR2 management module, you must read the Hardware
Installation Notes that shipped with the hardware.
NOTE
Although management modules are designed to be hot-swappable, you must upgrade the software
on all interface modules and management modules to the appropriate software release before
installing them. For more information on the appropriate software release, refer to the Hardware
Installation Notes that shipped with the management module.
Figure 13
FIGURE 13
RX-BI-MR
18
Management modules for all Brocade MLX Series and Brocade NetIron XMR routers (Continued)
Description
MLXe/MLX Gen2 management (M) module for 32-slot systems. Includes 4 GB RAM, 1
internal compact flash drive (2GB), 1 external compact flash slot with included 2GB card,
RS-232 serial console port and 10/100/1000 Ethernet port for management.
(MR2)
MLXe/XMR Gen2 management (X) module for 32-slot systems. Includes 4 GB RAM, 1
internal compact flash drive (2GB), 1 external compact flash slot with included 2GB card,
RS-232 serial console port and 10/100/1000 Ethernet port for management.
shows a management module front panel.
MR management module front panel
Console
Pwr
Active
Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide
10/100/1000
Port 1
Port 2
53-1002373-02