Brocade Communications Systems MLX Series Installation Manual page 353

Mlx series, netlron xmr series
Hide thumbs Also See for MLX Series:
Table of Contents

Advertisement

Fan Speed Hi: 70 - 113
state = 1 (FAN_STATE_MED)
max_ts_shut_off_count = 1
shut_off_count = 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
=== Thermal Sensor Control Block (THERMAL_SENSOR_TEST_RULE_STANDBY_MP) ===
Fan Speed Low: -1 - 60
Fan Speed Med: 57 - 70
Fan Speed Med-Hi: 67 - 80
Fan Speed Hi: 77 - 85
state = 0 (FAN_STATE_LOW)
max_ts_shut_off_count = 1
shut_off_count = 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
=== Thermal Sensor Control Block (THERMAL_SENSOR_TEST_RULE_MP_CPU) ===
Fan Speed Low: -1 - 60
Fan Speed Med: 57 - 70
Fan Speed Med-Hi: 67 - 80
Fan Speed Hi: 77 - 95
state = 1 (FAN_STATE_MED)
max_ts_shut_off_count = 1
shut_off_count = 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
=== Thermal Sensor Control Block (THERMAL_SENSOR_TEST_RULE_STANDBY_MP_CPU) ===
Fan Speed Low: -1 - 60
Fan Speed Med: 57 - 70
Fan Speed Med-Hi: 67 - 80
Fan Speed Hi: 77 - 95
state = 0 (FAN_STATE_LOW)
max_ts_shut_off_count = 1
shut_off_count = 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
Syntax: show fan-threshold
The output displays the following information.
TABLE 50
This field...
Thermal Sensor Control Block
(THERMAL_SENSOR_TEST_RULE_<
module>)
Fan Speed Low or Med or Med-Hi or
Hi
State = 0 (FAN_STATE_LOW)
max_ts_shut_off_count
shut_off_count = 0 0 0 0 0 0 0 0
Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide
53-1002373-02
Temperature threshold information for modules and fan speeds
Displays...
The temperature threshold information for the various modules. The
<module> parameter indicates the following:
MP – The active management module
STANDBY_MP – The standby management module
SNM – The switch fabric module
LP – An interface module
The current setting of the low and high temperature thresholds for the low,
medium, medium-high, and high fan speeds.
NOTE: As indicated in
For Brocade internal use only.
For Brocade internal use only.
For Brocade internal use only.
Managing the cooling system
Table 49
on page 333, the low fan speed for each
module does not have a default low temperature threshold value,
nor can you configure this value. The "-1" value that appears in the
Fan Speed Low field for each module is a Brocade internal value
only.