Brocade Communications Systems MLX Series Installation Manual page 251

Mlx series, netlron xmr series
Hide thumbs Also See for MLX Series:
Table of Contents

Advertisement

Brocade# show module
M1 (upper): Brocade router Mgmt Module
M2 (lower):
F0: Brocade router Switch Fabric Module
S1:
S2:
S3:
S4: Brocade router 4-Port 10Gig Module
S5: Brocade router 4-Port 10Gig Module
S6: Brocade router 4-Port 10Gig Module
S7:
S8:
Syntax: show module
The Status column shows the module status. The management module status can be one of the
following:
The switch fabric module status can be one of the following:
An interface module status can be one of the following:
Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide
53-1002373-02
Module
ACTIVE – The module is currently the active management module.
STANDBY – The module is currently the standby management module.
COMING UP – The module is coming up as the standby module. This status occurs if the
standby management module becomes the active module during a switchover.
ACTIVE – The module is up and running.
BAD – The management module cannot initialize the switch fabric module.
CARD_STATE_INIT – The system detects the module but the module is not up and running yet.
CARD_STATE_BOOT – The module is booting.
CARD_STATE_INTERACTIVE – The module is booting from interactive mode.
CARD_STATE_LP_SYNC – The software images are synchronized between the management
module and interface module.
CARD_STATE_SYNC – The system is currently synchronizing the software image between the
management module and interface module.
CARD_STATE_SOFTWARE_LOADED – The module has loaded the software image.
CARD_STATE_POWER_OFF – The module does not have power.
CARD_STATE_UP – The module is operating normally.
CARD_STATE_FAILED – The management module was unable to bring up an interface module.
If you see this status, make certain that the interface module is installed properly. For more
information, refer to
"Installing Brocade MLX-4 modules"
MLX-8 modules"
on page 167,
"Installing Brocade MLX-32 router modules"
CARD_DOWN_REASON_<explanation> – The module is in a nonfunctional state. This status
appears with an explanation for why the module is down. For example,
"CARD_DOWN_REASON_BOOT_FAILED." If the explanation does not help you resolve the
problem, contact technical support and provide the explanation included with this status.
Verifying proper operation
Status
Active
Active
CARD_STATE_UP
CARD_STATE_UP
CARD_STATE_UP
"Installing Brocade MLX-16 router modules"
on page 209.
Ports Starting MAC
4
000c.db80.0000
4
000c.db80.0000
4
000c.db80.0000
on page 158,
"Installing Brocade
on page 178, or
3
233