Brocade Communications Systems MLX Series Installation Manual page 56

Mlx series, netlron xmr series
Hide thumbs Also See for MLX Series:
Table of Contents

Advertisement

1
Router modules
Power supply requirements for BR-MLX-1GCx24-X interface modules
Table 16
Ethernet copper RJ45 interface module (BR-MLX-1GCx24-X).
TABLE 16
Router type
MLXe-4
MLX-4 and
Brocade NetIron
XMR 4000
MLXe-8
Brocade NetIron
XMR 8000
All 16-slot routers sixteen
All 32-slot routers thirty-two
24-port 1 Gbps fiber interface module
The 24-port 1 Gbps fiber interface module is available in the following formats:
The 24-port 1 Gbps fiber interface modules has 32 Mb of flash memory and provide 24 physical
ports, through which you can connect your router to other network routers. BR-MLX-1GFx24-X-ML
supports up to 512K IPv4 routes in hardware. BR-MLX-1GFx24-X supports up to 1M IPv4 routes in
hardware. The ML version can be upgraded to a X version through a software license. Please
contact Brocade to purchase the license upgrade.
NOTE
When you install BR-MLX-1GFx24-X and BR-MLX-1GFx24-X-ML modules, you must upgrade the
software on all interface modules and management modules to the appropriate software release.
For more information on the appropriate software release refer to the Hardware Installation Notes
that shipped with the modules.
38
lists the power supply requirements for each type of router when installing 24-port 1 Gbps
Power supply requirements for 24-port 1 Gbps Ethernet copper RJ45 interface module
Number of 24-port 1
Gbps Ethernet copper
RJ45 interface
module installed
three
four
four
seven
eight
eight
BR-MLX-1GFx24-X
BR-MLX-1GFx24-X-ML
Power supply requirements
one 1200W PSU
for 1+1 redundancy, install two 1200W PSU
two 1200W PSU
for 2+2 redundancy, install four 1200W PSU
one 1200W PSU
for 1+1 redundancy, install two 1200W PSU
two 1200W PSU
for 2+2 redundancy, install four 1200W PSU
three 1200W PSU
for 3+1 redundancy, install four 1200W PSU
two 1200W PSU
for 2+2 redundancy, install eight 1200W PSU
four 1200W PSU
for 4+4 redundancy, install eight 1200W PSU
four 2400W PSU
for 4+4 redundancy, install eight 2400W PSU
Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide